Design Spot 250 Pro™
©Elation Professional® 47 Design Spot 250 Pro™
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its
driver circuit on the main PCB). The focus motor is not located in the default position after
the reset.
13Er - Iris-error
This message will appear after the reset of the fixture and if the magnetic indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its
driver circuit on the main PCB). The Iris motor is not located in the default position after the
reset.